EXPLORING SHADING DEVICE STRATEGIES FOR COOLING EFFICIENCY IN THE DESIGN OF FIVE STAR HOTEL, BAUCHI, NIGERIA

dc.contributor.authorOTHNIEL, Abraham
dc.date.accessioned2021-08-26T08:01:29Z
dc.date.available2021-08-26T08:01:29Z
dc.date.issued2019-11
dc.descriptionA THESIS SUBMITTED TO THE SCHOOL OF POSTGRADUATE STUDIES AHMADU BELLO UNIVERSITY IN PARTIAL FULFILLMENT OF THE REQUIREMENTS FOR THE AWARD OF MASTERS DEGREE IN ARCHITECTURE DEPARTMENT OF ARCHITECTURE, FACULTY OF ENVIRONMENTAL DESIGN, AHMADU BELLO UNVERSITY, ZARIA, NIGERIAen_US
dc.description.abstractOver the years, the need for energy efficient building is on the increase as the current practice of building trends consumes a lot of energy. Buildings such as hotels consume a lot of electricity in providing comfort to the occupants through mechanical cooling. The most effective way of reducing cooling load is by reducing the solar heat gained by the building. External shading device are efficient in reducing cooling load when properly designed. The study aims to improve cooling efficiency by assessing shading device strategies with different variables. The variables that are considered in this are the horizontal shading device on the north and south orientation, the distance of shading device from wall and angle of shading device in the area of study in the hot -dry climate.The based case was modeled in Autodesk Revit and simulated using the Autodesk simulation Computational Fluid Dynamics (CFD). Autodesk simulation CFD assess for natural ventilation using indicators such as Predicted Mean Vote (PMV), Percentage Persons Dissatisfaction (PPD) and temperature. The result for the based cased model was +2.4(warm) of the PMV, 78% of PPD and the temperature of 32.01°C. While the concrete shading device at an angle of 70° with no distance from the wall on the north and south proved more comfortable over the other shading device strategies with a PMV of +0.2 (slightly neutral) and a PPD of 15% which is satisfactory, with a temperature of 27.01°C. In conclusion, the study discourages the use of 90° angle shading device with 200mm from wall with a PMV of +2.4 and a PPD of 80%, which has high discomfort level in the space. The 70° with no distance from the wall has shown significant improvement of natural ventilation and a 5°C reduction in temperature.en_US
dc.identifier.urihttps://kubanni.abu.edu.ng/handle/123456789/12581
dc.language.isoenen_US
dc.subjectEXPLORING SHADING DEVICE STRATEGIES,en_US
dc.subjectCOOLING EFFICIENCY,en_US
dc.subjectDESIGN,en_US
dc.subjectFIVE STAR HOTEL,en_US
dc.subjectBAUCHI,en_US
dc.subjectNIGERIAen_US
dc.titleEXPLORING SHADING DEVICE STRATEGIES FOR COOLING EFFICIENCY IN THE DESIGN OF FIVE STAR HOTEL, BAUCHI, NIGERIAen_US
dc.typeThesisen_US
Files
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
EXPLORING SHADING DEVICE STRATEGIES FOR COOLING EFFICIENCY IN THE DESIGN OF FIVE STAR HOTEL, BAUCHI, NIGERIA.pdf
Size:
2.18 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.62 KB
Format:
Item-specific license agreed upon to submission
Description: